EMC engineers provide professional electromagnetic compatibility (EMC) technology rectification and consulting services to clients.
EMC Rectification and Testing
EMC RectificationWe provide comprehensive EMC rectification solutions by analyzing product schematics, PCBs, and structures. Our goal is to address EMC issues at the source, ensuring rapid, efficient, cost-effective, and scalable solutions to maximize customer benefits.Contact Engineer
EMC DesignSemiware's EMC team has many years of EMC design experience. They are involved in all stages of product design, including schematics, PCB layout, and structural design, ensuring that the final product meets EMC standards and requirements.Contact Engineer
EMC TestingBased on customer design requirements and industry standards, we provide tailored testing solutions. Through Semiware's advanced EMC laboratory and partner labs, we offer efficient and accurate testing services, ensuring customers achieve high returns with low costs in EMC testing.Appointment of Lab
Electrostatic GeneratorEquipment Model: ESD61002TA
Test Standards: EN/IEC 61000-4-2 and GB/T 17626.2
Discharge Modes: Contact discharge, Air discharge
New Energy Surge GeneratorEquipment Model: SUG61005TBX
Open-circuit Voltage Waveform: 1.2/50μs, 10KV/15KV/20KV
Short-circuit Current Waveform: 8/20μs, 0.1~3kA
Surge Polarity: Positive/Negative, Positive-Negative Alternating
Combined Surge GeneratorEquipment model: PRM17626
Test standards: IEC61000-4-5 and GB/T17626.5
Open circuit output voltage: 1.2/50us, 10/700us
Open circuit and short circuit current: 8/20us, 5/320us
8/20μs Surge testerEquipment model: SUG61005TB
Voltage wave: 1.2/50μs, 0.2~6kV
Current wave: 8/20μs, 0.1~3kA
Output impedance: combined wave-2Ω; insulation impedance-500Ω
Automotive Jamming SimulatorEquipment model: ISO7637 P2.b4
Stable voltage: 12V±0.2V; 24V±0.4V
First voltage drop Us: 6 to 7V; 12 to 16V
Second voltage drop Ua: 2.5 to 6V; 5 to 12V
6KV lightning surge generatorEquipment model: SUR 700
Standard: IEC 61000-4-5 and GB/T 17626.5
Waveform: CCITT; 10/700us; 5/320us
Output voltage: 0.2~6kV
5m Faraday EMC Test ChamberEquipment Model: SAC-500
Frequency Range: 10kHz to 18GHz
Measurement Distance: 5.0m
Chamber Performance: Shielding, Attenuation, Voltage Standing Wave Ratio (VSWR), Noise
Conducted Immunity GeneratorDevice Model: CRF61006A-PC
Amplifier Power: 90W
Output Impedance: 50Ω
Voltage Standing Wave Ratio (VSWR): ≤1.2